  • describe

    Technical data * Allowed for 1 minute. ** Recommended values. Do not use ultra rapid or low peak fuses. Follow local rules. 230 V 115 V Built-in EMC, ACS55-01E- 01A4-2 02A2-2 04A3-2 07A6-2 09A8-2 01A4-1 02A2-1 No EMC, ACS55-01N- 01A4-2 02A

introduce
Technical data
* Allowed for 1 minute.
** Recommended values. Do not use ultra rapid or low peak fuses. Follow local rules.
230 V 115 V
Built-in EMC, ACS55-01E- 01A4-2 02A2-2 04A3-2 07A6-2 09A8-2 01A4-1 02A2-1
No EMC, ACS55-01N- 01A4-2 02A2-2 04A3-2 07A6-2 09A8-2 01A4-1 02A2-1
Motor continuous output power kW 0.18 0.37 0.75 1.5 2.2 0.18 0.37
hp 1/4 1/2 1 2 3 1/4 1/2
Frame size (no EMC) A A B C C A A
Frame size (EMC) A A B D D A A
Nominal ratings
Input voltage U 1 V 200…240 (+10/-15%) 110…120 (+10/-15%)
Continuous output current I 2 A 1.4 2.2 4.3 7.6 9.8 1.4 2.2
Max. output current I 2max * A 2.1 3.3 6.5 11.4 14.7 2.1 3.3
Output voltage U 2 V 0…U 1 , 3-phase 0…2×U 1 , 3-phase
Input current I 1 A 4.4 6.9 10.8 18.2 22.0 6.4 9.5
Switching frequency kHz 5 (max. 16)
Protection limits
Overcurrent (peak) A 4.4 6.9 13.5 23.9 30.9 4.4 6.9
Overtemperature 95°C / 203°F (heat sink)
Maximum wire sizes
Power terminals mm 2 2.5 (AWG 14) 4 (AWG 12) 2.5 (AWG 14)
Control terminals mm 2 1.5 (AWG 16)
Power losses W 21 32 51 74 103 24 35
Line fuse size**
IEC, type IEC269 gG A 10 16 16 25 32 10 16
UL, types CC and T A 10 15 20 25 30 10 15
Weight, Built-in EMC, ACS55-01E- kg (lb) 0.65 (1.4) 0.7 (1.5) 0.9 (2) 1.6 (3.5) 1.7 (3.7) 0.65 (1.4) 0.7 (1.5)
Weight, No EMC, ACS55-01N- kg (lb) 0.65 (1.4) 0.7 (1.5) 0.9 (2) 1.2 (2.6) 1.3 (2.9) 0.65 (1.4) 0.7 (1.5)